메뉴 건너뛰기
.. 내서재 .. 알림
소속 기관/학교 인증
인증하면 논문, 학술자료 등을  무료로 열람할 수 있어요.
한국대학교, 누리자동차, 시립도서관 등 나의 기관을 확인해보세요
(국내 대학 90% 이상 구독 중)
로그인 회원가입 고객센터 ENG
주제분류

추천
검색

논문 기본 정보

자료유형
학술저널
저자정보
울라 우바이드 (Department of Architecture, Graduate School of Hanyang University) 박재승 (Department of Architecture, Hanyang University)
저널정보
한국의료복지시설학회(현 한국의료복지건축학회) 의료·복지 건축(구 한국의료복지시설학회지) 의료·복지건축 : 한국의료복지건축학회 논문집 제22권 제4호
발행연도
2016.1
수록면
37 - 45 (9page)

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색

초록· 키워드

오류제보하기
Purpose: The purpose of this paper is to analyze a sample of single corridor, pod type and composite type of ICUs in terms of patient visibility, spatial configurations and nurse walking distance focused on Korean cases. Methods: The measures of static visibility were used to quantify the patient visibility (upper third part of the patient bed) from the nurse station. The measure of space programme and area distribution (patient zone percentage, staff zone percentage, circulation zone percentage, corridor length per bed, distance from nurse station (NS) to patient bed and departmental gross square meter (DGSM) per patient bed) were calculated by using AutoCAD and MS Excel programs. In the second step of analysis the values of space distribution were compared among the three type of ICUs as well as the nurse walking distance, DGSM per bed and gross factor. in the third step of analysis regression analysis was conducted for the possible correlation between visibility and space programme and area distribution factors as well as nurse walking distance factors. Results: (1) It was found that on average composite type unit offer highest value of patient visibility followed by pod type, while single corridor type unit offers the minimum value of patient visibility among the three plan typologies. (2) Average patient visibility and DGSM per bed shows a strong positive correlation ($r^2=0.75$) and p=0.026. (3) Average patient visibility and average distance from NS has a strong negative correlation ($r^2=0.78$), and P=0.02. (4) On average composite type unit offer the minimum walking distance from NS (7.22 meter) followed by pod type unit (8.35 meter) and single corridor (9.76 meter). (5) Maximum distance from NS was noted in single corridor (18.19 meter) followed by pod type unit (15.14 meter) and Composite type unit (11.1 meter). Implications: This study may contribute to the visibility analysis of existing and future ICU design in Korea to achieve maximum patient visibility and reduced nurse walking distance.

목차

등록된 정보가 없습니다.

참고문헌 (0)

참고문헌 신청

함께 읽어보면 좋을 논문

논문 유사도에 따라 DBpia 가 추천하는 논문입니다. 함께 보면 좋을 연관 논문을 확인해보세요!

이 논문의 저자 정보

최근 본 자료

전체보기

댓글(0)

0